Hi,

 

It might be due to the fact that you cannot have an Inlet Water Temperature (inlet3) below the Room temperature (inlet 1) with this component.

Inlet water temperature > Room temperature +0.5

An idea is thus to control the inlet3 to max(inlet temperature, room temperature +0.5)

 

Best regards,

 

David BLANDIN

CARDONNEL Ingénierie
Le confort durable du bâtiment
5 rue de la Mare à Tissier
91280 SAINT PIERRE DU PERRAY
Tél : 01 64 98 19 22 – Fax 01 64 98 25 09
david.blandin@cardonnel.fr

 

De : trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] De la part de Richard Thygesen
Envoyé : mercredi 25 avril 2012 16:15
À : TRNSYS-users@engr.wisc.edu
Objet : [TRNSYS-users] Radiator type 1231 with type 56

 

Hi.

I’m trying to use the radiator model type 1231 together with type 56.

 

Is it possible to connect air temperatures from a zone in type 56 to the type 1231 room temperature input? When I do that I get a run time error.

 

Best regards

richard.thygesen@mdh.se