[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Problem occurs when creating TRNED distributions



Billy -

In your lst file you have the following messages:

    Generated by Type     : Not applicable or not available
    TRNSYS Message     11 : The TRNSYS processor has reported an illegal variable name in an EQUATIONS or CONSTANTS card.  Equations or constants must not begin with END, INC, EQU or CON as these are protected codes required when reading the TRNSYS input file.  The offending variable name is listed below.
    Reported information  : CONTROLF
 
    TRNSYS Message     11 : The TRNSYS processor has reported an illegal variable name in an EQUATIONS or CONSTANTS card.  Equations or constants must not begin with END, INC, EQU or CON as these are protected codes required when reading the TRNSYS input file.  The offending variable name is listed below.
    Re! ported information  : CONTROLS
 
    TRNSYS Message     11 : The TRNSYS processor has reported an illegal variable name in an EQUATIONS or CONSTANTS card.  Equations or constants must not begin with END, INC, EQU or CON as these are protected codes required when reading the TRNSYS input file.  The offending variable name is listed below.
    Reported information  : CONTROLS1
 
    TRNSYS Message     11 : The TRNSYS processor has reported an illegal variable name in an EQUATIONS or CONSTANTS card.  Equations or constants must not begin with END, INC, EQU or CON as these are protected codes required when reading the TRNSYS input file.  The offending variable name is listed below.
    Reported information  : CONTROLS2
 
    TRNSYS Message     11 : The TRNS! YS processor has reported an illegal variable name in an EQUATIONS or CONSTANTS card.  Equations or constants must not begin with END, INC, EQU or CON as these are protected codes required when reading the TRNSYS input file.  The offending variable name is listed below.
    Reported information  : CONTROLS3

These variable names must be changed or it will not run.

Tim



----------------------------------
Timothy McDowell
Executive Vice President
Thermal Energy System Specialists, LLC
22 N. Carroll St, Suite 370
Madison, WI 53703
Phone: 608-274-2577
Fax: 608-278-1475



----- Original Message -----
From: "" <coolbilly1999@gmail.com>
Sent: Wed, March 28, 2012 9:59
S! ubject: Re: [TRNSYS-users] Problem occurs when creating TRNED distributions

Hi Jeff and David,
 
Thanks for the advice. But the variable name is from the components’ parameter, I don’t think I can change it. Unfortunately, I still can't locate the fatal error since there is no equation named OF. And I found it acts very weird, because sometime it can run the calculation in TRNED and no error comes up, and sometime this error comes up, especially after I linked the required data files under the same directory.It's kinda random, I have no clue how to solve this problem. So I turn to you for more helps. Please check the attached .trd file and let me know if you need ! more data file. Thanks very much.
 
Best regards,
Billy
 
Sent: Monday, March 26, 2012 6:53 PM
Subject: Re: [TRNSYS-users] Problem occurs when creating TRNED dis! tributions
 
Billy,

You used an illegal variable name.  Equation names cannot start with CON (nor EQU, SIM, etc.).  The TRNSYS processor looks at the first three letters of any line for key words and CON is the the beginning of CONstants.  So your variable named CONTROL is thereby illegal. 

On another note, always look for the first error in the list file and not the last error when debugging...

Jeff


Jeff Thornton
President - TESS, LLC

22 North Carroll Street - Suite 370
Madison WI 53703 USA

Phone: 608-274-2577
Fax: 608-278-1475
E-mail: thornton@tess-inc.com
Web: www.tess-inc.com



----- Original Message -----
From: "Billy Chen" <coolbilly1999@gmail.com>
Sent: Mon, March 26, 2012 17:39
Subject: [TRNSYS-users] Problem occurs when creating TRNED distributions

Hi TRNSYS users,
 
I met a problem when I tried to create a demo using TRNED. I cannot create the distributable and the error shown as below:
 
*** Fatal Error at time   :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available    TRNSYS Message     13 : The TRNSYS Processor has reported an error while trying to process EQUATIONS. The reported error was that an equal sign (=) did not follow the variable name. One common cause of this error is to have fewer equations that that specified in the EQUATIONS card. Please check the input file and re-run the simulation
    Reported information  : OF
 
I tried to locate the error but failed. I wonder if anyone has such problem before and please kindly give me some advice. Please check the attached LST file and let me know if more detailed information is need.
 
Thanks very much in advance.
 
Regards,
 
Billy

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users