Dear Karol,

Time base is modified in TRNBUILD, since it is used to evaluate heat transfert functions.
Open Outputs window in TRNBUILD.
At the top of the Outputs frame, you may modify TIME BASE under 'Calculate Transfer Functions'

Best regards

www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
62, Rue du Bolliet
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email

Le 20/12/2011 17:05, Karol Bandurski a écrit :

Hi,

 

Could you write me how can I modify time base?

 

I can’t find this

 

Regards

 

Karol

 

------------------------------------------------

Karol Bandurski MSc.

Institute of Environmental Engineering

Poznan University of Technology

www.ee.put.poznan.pl

www.put.poznan.pl

 

 

From: Adrien JEZEQUEL - ITF [mailto:a.jezequel@itf.biz]
Sent: Tuesday, December 20, 2011 4:56 PM
To: trnsys-users@cae.wisc.edu
Subject: Re: [TRNSYS-users] Timestep in Control cards and timebase in TRNBuild

 

Dear Heloise,
 
The time step must be shorter than the time base and the time base must be an integer multiple of the time step. So they can be differents.
 
Best regards

www.itf.biz
www.itf.biz

Adrien JEZEQUEL
Simulations Thermiques Dynamiques

ITF

62, Rue du Bolliet
73230 St Alban Leysse
FRANCE

Phone :
Fax :
Mail:

+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz

Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email


Le 20/12/2011 16:36, Heloise PELEN a écrit :

Hello,

 

Does the timestep defined in the control card in TRNSYS simulation studio has to be the same as the timebase defined in Outputs “Calculate transfer functions” in the BUI file ?

 

Thank you,

 

Regards,

 

Héloïse Pelen

TAMINE

Description : etamine_mail

heloise.pelen@etamine.coop

10 avenue des Canuts – 69120 Vaulx en Velin

Std : 04 37 45 34 20 / Fax : 04 37 45 41 38

Ld : 04 37 45 34 13 / Port : 06 65 07 41 77