Re: [TRNSYS-users] Error in simulation



Dear Mayank Bhatnagar,

Check the listing (*.lst) or log (*.log) if there is information about a specific component. This error is caused by a DLL  that doesn't match the proforma for that component. From the listing and log file, you will also see which DLL is calling what components.

Best regards,

Matt Duffy


----- Original Message -----
From: "Mayank Bhatnagar" <mayank.23aug@gmail.com>
Sent: Fri, November 4, 2011 5:53
Subject: [TRNSYS-users] Error in simulation

Dear all,

I am doing work on solar absorption cooling. Can anyone help me to find out component which had error given below and how to resolve it.

Fatal Error at time   :         0.000000

    Generated by Unit     : Not applicable or not available

    Generated by Type     : Not applicable or not available

    TRNSYS Message     48 : The TRNSYS processor has reported that an unrecognized control card was found while trying to read the input file.  This error can be caused by underspecifying a required number of items in the input file.  For example, specifiying only 9 parameters after a "PARAMETERS 10&qu! ot; card has been read can cause this error. The line that caused this error is listed in the reported information below.

    Reported information  : Total

 

Another question I want to ask whether it is possible to make a absorption refrigerator in trnsys.

 

Thank you,

 

Regards,

 

Mayank Bhatnagar

M.Tech. (Energy Engineering)

Malaviya National Institute o! f Technology,

Jaipur (INDIA)

contact no.- +91-9983816468

 