Muhammad, The collector model (and all the other models) calculate temperatures even when there is no flow. The collector, for example calculates a stagnation temperature of the fluid sitting in the collector. If you are seeing a temperature difference across the collector and the outlet is below the inlet temperature) then that may be due to thermal losses from the fluid sitting in the collector. Regards, David On 7/25/2011 09:48, muhammad waseem wrote: