Re: [TRNSYS-users] Maximum indoor temperature.
Didier,
You can use Type55 (periodic integrator) as it calculates various
statistics about its inputs (in addition to the integral). Pass the
indoor temperature to Type55 with the integration period set to the
entire year. Then use Type25 to print the Type55 "maximum value of input
over the integration period" output to a file.
Best,
David
On 4/12/2011 04:22, gossard@cict.fr wrote:
Hi TRNSYS-Users,
is it possible to save in a file the maximum indoor temperature of a
thermal zone over a year ?
Best regards,
Didier GOSSARD.
----------------------------------------------------------------