[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] open the former *.skp file with TRNSYS3D




Dear TRNSYS Users,

There seems to be this question very often. Please remember to work in the TRNSYS3D plugin (Open, Save, Close the *.idf) and NOT open/close/save in SketchUp (*.skp). You do not even need to save any *.skp.

Thank you,

Matt Duffy

----- Original Message -----
From: "王洋" <wanghongyang1767@gmail.com>
Sent: Thu, March 31, 2011 3:02
Subject: [TRNSYS-users] open the former *.skp file with TRNSYS3D

Dear all,

   How to open the former *.skp file correctly?

  When I open it, it always show! s as follows:







Sorry...the plugin has encountered an error.  This error may cause unpredictable behavior in the plugin--continue this session with caution!  It would probably be a good idea to exit SketchUp and start again.

For help, please contact the TRNSYS newsgroup by https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users .

 When reporting a bug, please include the error message and backtrace below (scroll down):

ERROR:
NameError
wrong constant name lorScaleInterface

BACKTRACE:
C:/Programme/Google/Google SketchUp 7/Plugins/Trnsys3d/lib/DialogManager.rb:31:in `const_get'
C:/Programme/Google/Google SketchUp 7/Plugins/Trnsys3d/lib/DialogManager.rb:31:in `restore_state'
C:/Programme/Google/Google SketchUp 7/Plugins/Trnsys3d/lib/DialogManager.rb:31:in `in! itialize'
C:/Programme/Google/Google SketchUp 7/Plugins/Trnsys3d/ lib/AsynchProc.rb:13:in `call'

Please give some suggustions!

Many thanks!

Br.

wang


2011/3/30 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. problem of IDF File from Sketchup8 in TRNBUILD (Pauline GELIN)
  2. Polymer PV-T absorber/ Type 560 (Philip Horn)
  3. trnsys3d pug-in sketchup8 : problem of adjacent wall for
     several others zones (Pauline GELIN)
  4. Re: Soil noding plugin for Googlesketchup. (Jeff Thornton)


---------- 已转发邮件 ----------
From: Pauline GELIN <p.gelin@katene.fr>
To: "TRNSYS-users@cae.wisc. edu" <TRNSYS-users@cae.wisc.edu>
Date: Wed, 30 Mar 2011 15:21:13 +0200
Subject: [TRNSYS-users] problem of IDF File from Sketchup8 in TRNBUILD

(SketchUp 8 (with some hours on Sketchup Pro eval), Operating system:Windows Vista)

 

From a 2D plan created in Nova, I had to create in 3D each zone/room separated to, after, copy them in one different trnsys3d zone for each.

After I had to identify each adjacent wall between all the rooms.

Then, I saved a IDf File and wanted to import it in TRNBuild.

 

There was this following message :

"Zone: ARCH 1 Airnode: ARCH1 (it is the nam of one of my rooms)

Wall must have an active layer or chilled ceiling layer or must be adjacent to a different zone

ADJ_WALL Surf 13

"

 

I don't understand what this means because this room includes 3 external walls and only one adj_wall.

And as on Sketchup we can't identify several adjacent rooms, I linked this adj_wall with the room with the most common surface which is even not 13m².

 

Is there anyone who ca! n tell me what I can change to succeed my import ?

 

Thank you so much for your help.

 

Best Regards,

 

Pauline Gelin



---------- 已转发邮件 ----------
From: Philip Horn <phorn@fraunhofer.org>
To: "trnsys-users@engr.wisc.edu" <trnsys-users@engr.wisc.edu>
Date: Wed, 30 Mar 2011 09:49:56 -0400
Subject: [TRNSYS-users] Polymer PV-T absorber/ Type 560

Dear All,

 

I want to simulate an unglazed  p! olymer PV-T collector in TRNSYS.

I was wondering if anyone has done this already, or could give some advice?

 

My plan is to take Type 560 and modify some parameters (heat conductivity, heat transfer coefficients (want to model rectangular “tubes”).

It must not be 100% accurate in the beginning, more like a first estimation.

 

Would be glad if someone could give some helpful input.

 

Best Regards,

Philip

 

 

Philip Horn
Fraunhofer Center for Sustainable Energy Systems CSE
25 First Street

Cambridge, MA 02141, U.S.A.
+1 617-575 7250 x139
phorn@fraunhofer.org
http://cse.fraunhofer.org/


The contents of this email and any files or attachments transmitted with it, unless otherwise indicated, are confidential and/or privileged.  The recipient may not use this message and any attachment for other than its intended purpose.

 



---------- 已转发邮件 ----------
From: Pauline GELIN <p.gelin@katene.fr>
To: "trnsys-users@cae.wisc.edu&qu! ot; <trnsys-users@cae.wisc.edu>
Date: Wed, 30 Mar 2011 18:23:19 +0200
Subject: [TRNSYS-users] trnsys3d pug-in sketchup8 : problem of adjacent wall for several others zones
 

SketchUp version:sketchup8
Operating system:windows xp


I am so sorry to ask a so easy question but I didn't find how to link a wall to several others zones.
Indeed, in the object info we can only choose one zone.
But, if I cut my zone into 2 parts and, for example, erase the adjacent wall to recreate it in trnbuild, after, there is no more interest to use sketchup and it would be quicker to do everything i! n trnbuild.

Is there anyone who already met this problem?
Do you have a solution ?

Thanks a lot in advance for your help.

Best regards,

Pauline Gelin.

 



---------- 已转发邮件 ----------
From: "Jeff Thornton" <thornton@tess-inc.com>
To: "Sébastien THOMAS" <sebastien.thomas@ulg.ac.be>, trnsys-users@cae.wisc.edu
Date: Wed, 30 Mar 2011 11:48:25 -0500 (CDT)
Subject: Re: [TRNSYS-users] Soil noding plugin for Googlesketchup.
<I am attempting to run the « Soil Noding 2D » plugin for sketchup.
Unfortunately I did not reach to build any mesh in the text file.   In
fact, I have the following messages but no mesh at t! he end of the
procedure :      TESS Soil & Slab Noding program for TRNSYS 17.  How far
the building is the temperature of the soil assumed unaffected by the
building….     Has someone good knowledge of this plugin ?  >

Did you answer the question posed by the plugin?  Put in something like 10
meters and hit enter.  Then continue to answer the questions until the
program informs you that the data file has been created.  We use it all
the time!

Jeff


Jeff Thornton
President - TESS, LLC

22 North Carroll Street - Suite 370
Madison WI 53703 USA

Phone: 608-274-2577
Fax: 608-278-1475
E-mail: thornton@tess-inc.com
Web: www.tess-inc.com



________________! _______________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users