Dear all, I´ve simulated a PV-installation and to check
that I´ve introduced the panel’s parameters properly I have entered
NOCT conditions like inputs. And I’ve contrasted the results that I’ve
obtained with the values of the manufacturer, and the temperature of the cell didn´t
match up. In my opinion, that happens because the temperature of the cell in .for
it isn´t very well defined. The
definition of cell temperature in fortran is TC=TA +
(SUN*(TCNOCT-TANOCT)/SUNNOCT*(1.-EFFREF/TAU_AL)) And
I think it should be TC=TA + (SUN*(TCNOCT-TANOCT)/SUNNOCT I
have no experience in photovoltaic, maybe i´m wrong. What type did you usually
use to simulate the panels? Thanks
in advance, Carol
Pascual |