Dear Stefano,

The wall thickness is limited to 1 meter in TRNBUILD.

You say condition does not fulfill the stability criteria, but have you try to increase your TIME BASE in TRNBUILD (TRNBUILD - Outputs - TIME BASE)?

I suggest you to increase you time base and check if results are physicaly correct. Time base must be a mutliple of your time step.

Best regards

www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
62, Rue du Bolliet
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email

Le 21/03/2011 18:15, Avesani Stefano a écrit :

Dear all,

 

I need to simulate the behavior of a building with big thermal mass (old church, circa 90 cm stone wall).

 

Unfortunately, this condition does not fulfill the stability criteria.

Which is the best way to simulate this case? Would it make sense to create another adjacent thermal zone with no air mass capacitance and with the external wall as half of the massive original wall?

 

Thanks for helping and suggestions

 

Stefano

 