[TRNSYS-users] Type66 EES and TRNSYS



Dear all,

I am currently using the Type66 object for exchanging data between TRNSYS and ees. At first it worked very well, but when I want to receive more than 34 inputs from ees, TRNSYS alway generates an error: "Error converting clipboard data to numbers." After searching for this problem, I found that the problem was situated in the Type66 component, which only reads the first 512 characters from the clipboard. The suggested solution was to modify the value of szdelivertext to a higher number and recompile it.(https://mailman.cae.wisc.edu/pipermail/trnsys-users/2009/004540.html) I modified the value of szdelivertext to 40 000 in stead of the standard 4000, but the result stayed the same.

Can anyone suggest a solution for this problem?

Best regards,
--
Simon Binnemans
Onderzoeksmedewerker Kenniscentrum Energie
KHK
Kleinhoefstraat 4
2440 GEEL
T: +32(0)14 56 23 10
F: +32(0)14 58 48 59
http://www.khk.be