[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type42 with Performance data file



Benoît,
 That is quite strange! I had to make two changes in order to get the project to run. First, the parameters for the number of 1st independent variables and 2nd independent variables are switched. It should be 9 2nd independents and 4 1st independents. The convention is that the X1 values (the values of the first independent variable) always appear closest to the data itself. (In order to make that change, I had to modify the allowed max in the Type42b proforma). There also seems to be some strange invisible characters in your data file. I retyped the two lines of independent variable values then I pasted in the values of the dependent variables, saved it as a new file and it ran fine.
Best,
 David


On 2/10/2011 07:24, COGNE Benoit (Axima Seitha) wrote:
Dear all,
 
I try to use the Type42d with performance data file.
I get an error that I can not solve.
 
TRNSYS Message     98 : Unrecognized variable name or bad data card. TRNSYS was looking for a numerical value or the name of a variable defined in an equation/constant and instead it found the data in "reported information" below.
    Reported information  : ÿþ2 0 . 0   3 0 . 0   4 0 . 0   5 0 . 0   6 0 . 0   7 0 . 0   8 0 . 0   9 0 . 0   1 0 0 . 0
 
 
ÿþ2 0 . 0   3 0 . 0   4 0 . 0   5 0 . 0   6 0 . 0   7 0 . 0   8 0 . 0   9 0 . 0   1 0 0 . 0
                                                                                                                                                                    ;                                                                                                                                                                      ;                                                                                                                                                                      ;                                                                                                                                                                      ;                                                                                                                                                                      ;                                                                                   
          $           
 
Can anyone help ?
 
Best regards
 
Benoît COGNE 
Développement Efficacité Energétique 
___________________________________________________



Direction Commerciale
 
46 Boulevard de la Prairie au Duc
BP 40119 - 44201 Nantes Cedex 02 
Tel. 02 40 41 00 81
mail: benoit.cogne@aximaseitha-gdfsuez.com

www.aximaseitha-gdfsuez.com

P Pensez à l'environnement avant d'imprimer ce message

 
GDF SUEZ Mail Disclaimer: http://www.gdfsuez.com/disclaimer/disclaimer-fr.html
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com