Re: [TRNSYS-users] How can I increase the max allowable number of outputs in TRNSYS ( Problem in recompile and relink the trndl.dll file)



Mehdi,
  If you have either the Compaq or Intel Visual Fortran compiler, recompiling and relinlinking the TRNDll isn't too complex. Look in the ..\TrnsysXX\Compilers\ directory and find the compiler project that is appropriate to your compiler. Open either the workspace (in the case of Compaq) or the solution (in the case of Intel). The maximum number of outputs is set in TrnsysConstants.f90. Once you have increased the maximum, select "rebuild solution" or "rebuild all" from the "build" menu. before you do, however, save a copy of your original TRNDll.dll as the "rebuild" will overwrite it!
Kind regards,
 David

On 2/11/2011 09:02, Mehdi Shahrestani wrote:

Dear Everybody

 

I have got a problem in running a simulation.

When I run a model, this error comes up. The error is mentioning that the model exceed the max number of outputs.

 

 

I do not want to reduce the number of outputs because I need all of them. I want to increase the max allowable outputs of TRNSYS. But I do not know how can I recompile and relink the trndll.dll file.

 

I was wondering if anybody could give me advice to tackle the issue.

 

Many thanks

Mehdi

 

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com