Davide,
  TRNBuild refers to all opaque surfaces as "walls" whether they are in fact floors, roofs, ceilings, or doors. I would recommend adding your doors as "resistive only" because they usually have such low mass that their transfer function coefficients cannot be resolved. If your doors have significant amounts of glass area then treat them as windows instead of treating them as doors.
Best,
 David


On 1/30/2011 09:19, davide disco wrote:
Goodmorning,
I am a new TRNSYS' user and I have same trouble with TRNBuild.
For example, how can I add doors to my thermal model?
Thanks in advance.