Re: [TRNSYS-users] Own height factor of large opening in TRNFlow



Dear Wang,

the own height factor is described in the COMIS reference manual / user guide on page 83 (et seqq): it is the cosine of the angle between the window plane and a vertical plane -> for vertical windows it is 1 and for horizontal windows it is 0. Hence, in your case it should be 1.