Send TRNSYS-users mailing list submissions to
trnsys-users@cae.wisc.edu
To subscribe or unsubscribe via the World Wide Web, visit
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
trnsys-users-request@cae.wisc.edu
You can reach the person managing the list at
trnsys-users-owner@cae.wisc.edu
When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:
1. Re: solar radiation units of weather data type109
(Kersken, Matthias)
2. New component creation with g95 (???)
---------- 已转发邮件 ----------
From: "Kersken, Matthias" <Matthias.Kersken@ibp.fraunhofer.de>
To: "Laia Cases - iMat" <lcases@imat.cat>, <trnsys-users@cae.wisc.edu>
Date: Wed, 24 Nov 2010 13:57:01 +0100
Subject: Re: [TRNSYS-users] solar radiation units of weather data type109
Dear Laia!In the climatefile W/m² are/have to be used but the output of Type109 in the simulation studio is kJ/m²h (factor 3.6).With kind regards,Matthias Kersken---
Dipl.-Ing. Matthias Kersken
Wissenschaftlicher Mitarbeiter / Abteilung EnergiesystemeFraunhofer-Institut für Bauphysik
Institutsteil HolzkirchenFraunhoferstraße 10
83626 ValleyeMail: Matthias.Kersken@ibp.fraunhofer.de
Telefon 08024 / 643-204
Telefax 08024 / 643-366
www.ibp.fraunhofer.de
Dipl.-Ing. Matthias Kersken
Research Associate / Department Energy SystemsFraunhofer Institute for Building Physics
Branch HolzkirchenFraunhoferstraße 10
D-83626 ValleyeMail: Matthias.Kersken@ibp.fraunhofer.de
Phone +49 8024 / 643-204
Fax +49 8024 / 643-366
www.ibp.fraunhofer.de
---
hi everybody,
Von: Laia Cases - iMat [mailto:lcases@imat.cat]
Gesendet: Mittwoch, 24. November 2010 12:47
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] solar radiation units of weather data type109
I am getting confused about the units of solar radiation (direct beam, etcc) when using type109: In mathematical reference , 5-432, it says in W/m2, but in studio type109 in out description says kJ/hm2.
what are the correct one?
thanks in advance
Laia
--
Laia Cases
Unitat de Condicionament Tèrmic
iMat - Centre Tecnològic de la Construcció
lcases@imat.cat
www.imat.catWellington 23 · E-08018 Barcelona
T +34 93 553 97 95
F +34 93 553 97 96
Imprimiu aquest document només si és necessari
---------- 已转发邮件 ----------
From: 김영일 <yikim@seoultech.ac.kr>
To: TRNSYS users <trnsys-users@cae.wisc.edu>
Date: Sun, 28 Nov 2010 17:56:59 +0900 (KST)
Subject: [TRNSYS-users] New component creation with g95Dear TRNSYS users,
I am trying to create a new component with g95 compiler.
I had no trouble creating one with TRNSYS 16.1 but since I
have upgraded to TRNSYS 17, it's not working any more.
With TRNSYS 17, the structure of the new component generated
by Simulation Studio is different than it used to be. I noticed that
the arguments are no longer existent and command lines with
$$ are newly seen. I don't see the output arrays any more.
Is this normal with TRNSYS 17 or did I do something wrong?
Following lines which were automatically inserted with Simulation Studio
are in error.
$$PARAMETER_DEFINITIONS
$$INPUT_DEFINITIONS
I am attaching two files which I hope will explain my situations.
One is a fortran file generated by Simulation Studio.
This other one is a list of error comments shown after I ran
g95 compile.bat.
Thanks.
Youngil Kim, SNUST
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users