Alain, If you are using TRNSYS 17, error 427 should be: "An OUTPUT from the specified component model has been written to the global OUT array in a location beyond the allocated number of outputs from this model. Please check the component carefully to insure that INFO(6) is set correctly. The simulation has been aborted to avoid problems caused by over-writing the outputs from other component models" if that is true then the error message should also indicate which unit number and which Type number caused the error. If it is a standard component (ie a Type number between 1 and 200) then please send the project (*.tpf and the data files needed to run the project) to me and I will see about debugging it. Best, David On 10/22/2010 14:08, moreau.alain@lte.ireq.ca wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |