Dear Wang,

You can go to the toolbar and by clicking "Calculate" ---> "Open" ---> "External Files" after running the simulation. There are .sum and .prn files which contain data. (For the Type56 building). 
You can also link every component you want to get data from with a Type25c (Printer) from the output component list. The ".out" file will be listed also in the "External Files" as I described.

Hope that helps,
Elias Sasati

2010/10/15 王洋 <wanghongyang1767@gmail.com>
Dear all,
 
How to get the simulation data from TRNSYS? How to export them from simulation software into .txt format etc. ? I want to use these simulation data and values.
 
thanks!
 
br.
 
wang

2010/10/14 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. Re: Problem with Type42b data file in TRNSYS17 (David BRADLEY)


---------- 已转发邮件 ----------
From: David BRADLEY <d.bradley@tess-inc.com>
To: Philipp Lezajic <philipp.lezajic@yahoo.de>
Date: Thu, 14 Oct 2010 10:17:00 -0500
Subject: Re: [TRNSYS-users] Problem with Type42b data file in TRNSYS17
Philipp,
  Make sure that you have a recent Trnsys17 release (the most recent, I believe is 17.00.0019). I seem to recall that one of the earlier releases had a bug in the InterpolateData routine (which is called by Type42). If you do have the most recent version, please send your input file along and I will have a look.
Regards,
 David


On 10/13/2010 09:02, Philipp Lezajic wrote:
Hi,

I am using performance data file/type42b with 2 independent and 1 dependent variable

20.0 50.0
10.0 20.0 30.0
1
2
3
4
5
6

In TRNSYS 17 the output for the dependent variable is always "6", no matter what values the independent variables have. The performance data file and the deck file are attached. In TRNSYS 16 the same performance data file works and the output of the dep. variable is as expected.

Has anyone come across this before? Thanks in advance for help!

regards Philipp


_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users