Today's Topics:
1. Running Trnsys in batch files (Kerl, Marion (SCR US EXT))
2. Re: Running Trnsys in batch files (Timothy McDowell)
3. Re: Determination of heat tranfer rate of walls in Type56
(Matt Duffy)
4. Re: TRNSYS 3D and shading (GANAPATHY.IYER@Thermaxindia.com)
5. Re: Determination of heat tranfer rate of walls in Type56
(tommaso.toppi@polimi.it)
---------- 已转发邮件 ----------
From: "Kerl, Marion (SCR US EXT)" <marion.kerl.ext@siemens.com>
To: <trnsys-users@cae.wisc.edu>
Date: Mon, 4 Oct 2010 13:36:35 -0700
Subject: [TRNSYS-users] Running Trnsys in batch files
Hi everyone,
This is my first post here in this list. I want to couple BCVTB with TRNSYS. So, I have two questions regarding the topic to run TRNSYS in batch files.
1. Is it possible to run a dck-file from TRNSYS with parameters? With a command like this: "C:\Trnsys16_1\Exe\TRNExe.exe" "C:\Trnsys16_1\Examples\SDHW\sdhw.dck" /n 150 200 300
Assumed the model in TRNSYS requires start values.
2. Furthermore I tried to run the example from the manual. But every time when I run the example "C:\Trnsys16_1\Exe\TRNExe.exe" "C:\Trnsys16_1\Examples\SDHW\sdhw.dck" /n
I will get an error message:
---------------------------
TRNEXE: TRNExe.exe - Unable To Locate Component
---------------------------
This application has failed to start because libmx.dll was not found. Re-installing the application may fix this problem.
---------------------------
OK
---------------------------
I don’t understand this message, because the libmx.dll is already in C:\TRNSYS16_1\UserLib\DebugDLLs and C:\TRNSYS16_1\UserLib\ReleaseDLLs and C:\TRNSYS16_1\UserLib. What’s wrong??
Thank you very much in advance.
Marion
---------- 已转发邮件 ----------
From: "Timothy McDowell" <mcdowell@tess-inc.com>
To: "Kerl, Marion (SCR US EXT)" <marion.kerl.ext@siemens.com>, trnsys-users@cae.wisc.edu
Date: Mon, 4 Oct 2010 15:45:44 -0500 (CDT)
Subject: Re: [TRNSYS-users] Running Trnsys in batch files
Marion -
I have just completed a Type for TRNSYS version 17 that will allow TRNSYS
to be used in BCVTB. It is still a beta version, but let me know if you
would like to test it out.
I do not quite understand your questions - are you trying to run directly
from the command line in windows or are you trying to execute TRNSYS from
BCVTB?
Regards,
Tim
----------------------------------
Timothy McDowell
Executive Vice President
Thermal Energy System Specialists, LLC
22 N. Carroll St, Suite 370
Madison, WI 53703
Phone: 608-274-2577
Fax: 608-278-1475
----- Original Message -----
From: "Kerl, Marion (SCR US EXT)" <marion.kerl.ext@siemens.com>
Sent: Mon, October 4, 2010 15:36
Subject:[TRNSYS-users] Running Trnsys in batch files
Hi everyone,
This is my first post here in this list. I want to couple BCVTB with
TRNSYS. So, I have two questions regarding the topic to run TRNSYS in
batch files.
1. Is it possible to run a dck-file from TRNSYS with parameters?
With a command like this: "C:\Trnsys16_1\Exe\TRNExe.exe"
"C:\Trnsys16_1\Examples\SDHW\sdhw.dck" /n 150 200 300
Assumed the model in TRNSYS requires start values.
2. Furthermore I tried to run the example from the manual. But every
time when I run the example "C:\Trnsys16_1\Exe\TRNExe.exe"
"C:\Trnsys16_1\Examples\SDHW\sdhw.dck" /n
I will get an error message:
---------------------------
TRNEXE: TRNExe.exe - Unable To Locate Component
---------------------------
This application has failed to start because libmx.dll was not found.
Re-installing the application may fix this problem.
---------------------------
OK
---------------------------
I don’t understand this message, because the libmx.dll is already in
C:\TRNSYS16_1\UserLib\DebugDLLs and C:\TRNSYS16_1\UserLib\ReleaseDLLs and
C:\TRNSYS16_1\UserLib. What’s wrong??
Thank you very much in advance.
Marion
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
----- End of original message -----
---------- 已转发邮件 ----------
From: Matt Duffy <duffy@tess-inc.com>
To: "a8304506@graduate.hku.hk" <a8304506@graduate.hku.hk>
Date: Mon, 4 Oct 2010 16:55:25 -0500
Subject: Re: [TRNSYS-users] Determination of heat tranfer rate of walls in Type56
Did you try QCOMO or the QCOMI NType outputs yet?
Best regards
Matt Duffy
Thermal Energy Systems Specialists
Sent from my mobile wireless device. Please excuse any typos.
On Oct 4, 2010, at 6:56 AM, a8304506@graduate.hku.hk wrote:
> Hello, everyone.
>
> I want to calculate the heat transfer rate through particular walls in Type56.
> I have tried to output the NTYPE82 (wall gain) but the value is always zero.
> Can anyone advise which other output should I use? Thank you!
>
> Best Regards
> LEE, Chun Kwong
> Division of Building Science and Technology
> City University of Hong Kong
>
>
>
>
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users@cae.wisc.edu
> https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
---------- 已转发邮件 ----------
From: GANAPATHY.IYER@Thermaxindia.com
To: mesude bayrakci <mesudebayrakci@gmail.com>
Date: Tue, 5 Oct 2010 10:47:57 +0530
Subject: Re: [TRNSYS-users] TRNSYS 3D and shading
Dear Mesude,
Click on escape key two times. Your focus in on the old zone, release the focus by pressing escape
mesude bayrakci <mesudebayrakci@gmail.com> 10/04/2010 09:01 PM
ToTRNSYS-users@cae.wisc.edu cc Subject[TRNSYS-users] TRNSYS 3D and shading
Hello,
I tried to create a new shading group tool after I created new zone.However, an error showed up and said
" Zone should be added at the top level of a SketchUp model"
I tried to do that in difference places, always it says the same error.
Any idea?
Thank you._______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
================================================================================================================
DISCLAIMER :
The information in this email is confidential and may be legally
privileged.It is intended solely for the addressee. Access to this email by anyone else is unauthorized.If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. When addressed to our clients any opinions or advice contained in this email are subject to the terms and conditions.
---------- 已转发邮件 ----------
From: tommaso.toppi@polimi.it
To: Matt Duffy <duffy@tess-inc.com>
Date: Tue, 05 Oct 2010 09:42:54 +0200
Subject: Re: [TRNSYS-users] Determination of heat tranfer rate of walls in Type56
I'm trying to obtain the heat transfer coefficient, so the problem is similar.
I tried with QCOMI for a surface and dividing it by the temperature difference between the surface and the star node, but I found non-physical results.
Is there any heat flux I have to subtract to QCOMI before?
What about QABSI? (QCOMI - QABSI) shouldn't be the convective heat flux?
Thank you
Tommaso Toppi
Def. Quota Matt Duffy <duffy@tess-inc.com>:
Did you try QCOMO or the QCOMI NType outputs yet?
Best regards
Matt Duffy
Thermal Energy Systems Specialists
Sent from my mobile wireless device. Please excuse any typos.
On Oct 4, 2010, at 6:56 AM, a8304506@graduate.hku.hk wrote:
Hello, everyone.
I want to calculate the heat transfer rate through particular walls in Type56.
I have tried to output the NTYPE82 (wall gain) but the value is always zero.
Can anyone advise which other output should I use? Thank you!
Best Regards
LEE, Chun Kwong
Division of Building Science and Technology
City University of Hong Kong
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
----------------------------------------------------------------
This message was sent using IMP, the Internet Messaging Program.
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users