You could try even
smaller time-steps, I’ve models with timestep: 0,03125 (n=5), 0,015625 (n=6)
and even 0.0078125 (n=7). It just takes a while before it’s finished
calculating.
Mariëlle
Van:
frodriguezpc@labein.es [mailto:frodriguezpc@labein.es]
Verzonden: maandag 27 september
2010 9:11
Aan: Mariëlle Nuchelmans
CC: trnsys-users@cae.wisc.edu
Onderwerp: Re: [TRNSYS-users]
digging into trnflow convergence problems
Thanks Mariëlle,
I
have unsuccessfully tried several timesteps, from 0.0125 of an hour, to 0,1 and
even one hour, which are obviously too large. The only way I can get the
simulation finished is to input very large limit velues for warning and
errors...
I
am curious about this thing with interior and exterior temperatures, and was
wondering if some conclusions about stack performance could be extracted from
this...
Thanks,
Francisco
Rodríguez Pérez-Curiel
TECNALIA-Construcción
Parque Tecnológico, Edificio 700. E-48160 Derio (Bizkaia) (SPAIN)
Tel. +34 94 607 33 00, Fax. +34 94 607 33 49
francisco.rodriguez@tecnalia.com,
www.tecnalia.com
**************** AVISO LEGAL **************** DISCLAIMER
******************
Este mensaje es personal y confidencial y su uso no autorizado está prohibido
legalmente. Si usted no es el destinatario, proceda a borrarlo, sin reenviarlo
ni conservarlo.
This message is personal and confidential, unauthorised use is legally
prohibited. If you are not the intended recipient, delete it without resending
or backing it.
**************************************************************************************
Mariëlle Nuchelmans
<M.Nuchelmans@chri.nl>
27/09/2010 08:08
|
Para
|
"frodriguezpc@labein.es"
<frodriguezpc@labein.es>, "trnsys-users@cae.wisc.edu"
<trnsys-users@cae.wisc.edu>
|
cc
|
|
Asunto
|
RE: [TRNSYS-users] digging into trnflow
convergence problems
|
|
Maybe you have already tried it, but you can make
your simulation time step smaller (in steps of 1/(2^n))
Kind regards,
Mariëlle
Van: frodriguezpc@labein.es
[mailto:frodriguezpc@labein.es]
Verzonden: maandag 27 september 2010 6:24
Aan: trnsys-users@cae.wisc.edu
Onderwerp: [TRNSYS-users] digging into trnflow convergence problems
Dear all:
I am working on a trnflow simulation (an apartment with passive stack
exhausts), and having some convergence problems. After looking at it I have
found these problems occur whenever the outside temperature gets significantly
higher than the interior temperature, as you can see in the attached image. Any
suggestion on how to deal with this?
Thanks,
Francisco Rodríguez Pérez-Curiel
TECNALIA-Construcción
Parque Tecnológico, Edificio 700. E-48160 Derio (Bizkaia) (SPAIN)
Tel. +34 94 607 33 00, Fax. +34 94 607 33 49
francisco.rodriguez@tecnalia.com,
www.tecnalia.com
**************** AVISO LEGAL **************** DISCLAIMER
******************
Este mensaje es personal y confidencial y su uso no autorizado está prohibido
legalmente. Si usted no es el destinatario, proceda a borrarlo, sin reenviarlo
ni conservarlo.
This message is personal and confidential, unauthorised use is legally
prohibited. If you are not the intended recipient, delete it without resending
or backing it.
**************************************************************************************