[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] Energy demands of a buildng.
Dear Elias Sasati,
Have you turned on heating and cooling in TRNBuild and defined set temperatures in the type managers? This is required to output the energy demand of the building.
Best regards,
Knut Erik Enerstvedt
>Dear TRNSYS users,
>After creating my building in
TRNBuild, setting the wall types, creating the zones, manage the
schedules and doing all the >requirements, I try to simulate the bulding
in different climate data.
>I am creating a new multizone project in TRNSYS Simulation Studio
and let the program guide me. Then I double click on the building >icon
I am replacing the path with the location of my .bui file in "External
Files" tab.
>I change the parameters of the Temperature plotter (Type 65d) to meet the case and connect the:
- "temperature air node of ZoneN" (TAIR_N) -> "left axis variable N"
> and then the:
- (sens. energy demand of zone N) QsensN -> "right variable axis N".
> When I run the simulation I am getting only the room temperatures without the energy demand plotted.
>Any ideas how I can get the energy demand (Q) for
heating and cooling according to the climate data to keep the zone
temperatures >fixed to my prefernce. I am using TNSYS 16.
>Thank you for your time,
>Elias Sasati