Dear all,
 
Ihave a question:
The Restaurant Trnflow Example doesn't RUN, it shows "Parameters for Trnflow are missing", then I checked it, obviously, all the Value of Trnflow is 0. Why is it like that? Did the TRNSYS Corporation not SET the Value or  the Parameters are missing after the installtion? Please explain in detail! thanks!
 
Br.
 
wang

2010/8/4 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. Re: TRNSYS-users Digest, Vol 68, Issue 7 (ghetu mariana)
  2. Re: Virtual window in TRNBUILD (Marion Hiller)
  3. Re: Internal walls and Trnsys3d (Marion Hiller)
  4. TRNFlow and COMIS stand-alone version (Marion Hiller)


---------- 已转发邮件 ----------
From: ghetu mariana <ghetu_mariana@yahoo.co.uk>
To: trnsys-users@cae.wisc.edu
Date: Wed, 4 Aug 2010 09:07:03 +0000 (GMT)
Subject: Re: [TRNSYS-users] TRNSYS-users Digest, Vol 68, Issue 7

Hello,


Does anyone know how can I have one iteration per timestep within Type 56? I need to insert something like: Tint(INFO(7)=0) = Tint(INFO(7)=1).

 Is there a way to do this without changing the code of Type 56?


Thanks for any info.


Mariana GHETU



From: "trnsys-users-request@cae.wisc.edu" <trnsys-users-request@cae.wisc.edu>
To: trnsys-users@cae.wisc.edu
Sent: Wed, 4 August, 2010 7:05:11
Subject: TRNSYS-users Digest, Vol 68, Issue 7

Note: Forwarded message is attached.

Send TRNSYS-users mailing list submissions to
    trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
    https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
    trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
    trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:

  1. TRNSYS solar modeling position posted at NREL (Blair, Nate)
  2. Re: modify layer library (David Bradley)
  3. Re: Creation of a New Type and Error message 105
      (Soteris Kalogirou)
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users



---------- 已转发邮件 ----------
From: "Marion Hiller" <hiller@transsolar.com>
To: trnsys-users <trnsys-users@engr.wisc.edu>
Date: Wed, 4 Aug 2010 11:19:51 +0200
Subject: Re: [TRNSYS-users] Virtual window in TRNBUILD
Dear Marcello,
 
the window in the TESS lib isn't defined correctly.
I'm not sure if  TESS released a corrected version of the Library.
Maenwhile you can use the vitual window of the AMERICAN or GERMAN Library.
they should worl without a problem.
 
Marion Hiller
 
 
Dipl.-Ing. Marion Hiller
TRANSSOLAR Energietechnik GmbH
Munich - New York - Stuttgart + 49.711.67976.0

KlimaEngineering- Technologien für energieeffizientes Bauen und Nutzerkomfort in Gebäuden
Transsolar Energietechnik GmbH, Curiestrasse 2, 70563 Stuttgart / Amtsgericht Stuttgart - HRB 23347 / USt-IdNr.: 99073/00911
Geschäftsführer: Dipl.Ing. Matthias Schuler, Dipl.Ing. Thomas Auer, Dipl.Phys. Stefan Holst
 


   Von: Marcello Caciolo [mailto:mcaciolo@hotmail.com]
Gesendet: Freitag, 30. Juli 2010 10:33
An: trnsys-users@engr.wisc.edu
Betreff: [TRNSYS-users] Virtual window in TRNBUILD

Dear TRNSYS users,

I am trying to model a zone with an opened window in TRNSYS 16. For the thermal model, I use the type56 with a window of the type: "Virtual (open or nonexistent) Window" (WINID 1) from TESS Library.

Unfortunately, when I start the simulation, I get the following error:

"Une valeur négative ou supérieure à 1 a été trouvé pour l'absorption non visuelle W4_front pour la fenêtre no 1 : abs_nonvis = -.0008717874 à l'angle = 0"
(A value negative or greater than 1 was found for nonvisual absorption W4_front for Window-ID   1 : abs_nonvis = -.0008717874 at angle = 0)

I see that other people reported this problem in this forum, but I have not found any solution.

Do you know how to solve this issue?

Thanks in advance for your attention.

Best regards,

Marcello CACIOLO

-- 
--------------------------------------------------------------------------------

Marcello CACIOLO
Ingénieur de Recherche  Centre Energétique et Procédés - Mines ParisTech
60, Bd Saint-Michel  75272 Paris Cedex 06 France 
Tél : +33 (0)1 40 51 94 21 Fax : +33 (0)1 40 51 94 49
E-mail: marcello.caciolo@ensmp.fr

--------------------------------------------------------------------------------



---------- 已转发邮件 ----------
From: "Marion Hiller" <hiller@transsolar.com>
To: trnsys-users <trnsys-users@cae.wisc.edu>
Date: Wed, 4 Aug 2010 11:28:06 +0200
Subject: Re: [TRNSYS-users] Internal walls and Trnsys3d
Dear Pablo,
 
the 3D detailed radiation mode of TRNSYS 17 are restricted to convexe zones.
Therefore no "internal walls" blocking views are allowed to be defined.
 
You may split your zone into convex several convex zones or increase the capacity of the air node.
 
At the moment we are working on developing and incoorperating improved algorithms which can
handle concave zones.
 
Marion 


   Von: Direccion [mailto:direccion@idienergia.es]
Gesendet: Dienstag, 3. August 2010 13:56
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] Internal walls and Trnsys3d

Hello.

 

There’s no “internal wall” in “Constructions”  when I try to draw a building with Trnsys3d. I can’t add that walls inside Trnbuild 17, because I need to use the 3D Model.

¿Somebody knows how can I model these types of walls and, at the same time, model with Trnsys 3D?

 

Thanks to all.

 

PABLO EGUÍA

Director Técnico

IDi Energia.

C/Padre Ramón María Aller, nº 6, 1ºD

36201 – VIGO

Pontevedra



---------- 已转发邮件 ----------
From: "Marion Hiller" <hiller@transsolar.com>
To: trnsys-users <trnsys-users@cae.wisc.edu>
Date: Wed, 4 Aug 2010 11:46:09 +0200
Subject: [TRNSYS-users] TRNFlow and COMIS stand-alone version
Dear Wang,
 
TRNFlow is an integrated version of COMIS into Type 56.
If you want use TRNbuild/TRNFlow you need to define your airflow network within TRNBuild.
Within the Studio create a multizone building project. You don't need a COMIS version at all.
 
For using the stand-alone version of COMIS in TRNSYS, the option create "COMIS project" of the Studio can be used.
 
Marion
 

   Von: 王洋 [mailto:wanghongyang1767@gmail.com]
Gesendet: Freitag, 30. Juli 2010 18:13
An: trnsys-users@cae.wisc.edu
Betreff: Re: [TRNSYS-users] TRNSYS-users Digest, Vol 67, Issue 68

hi every one!

 
I build a COMIS project, but it shows "the full version of COMIS is not installed correctly, the demo version be used......." How to make it? I had TRNSYS/TRNFLOW.
 
thans!
 
wang

2010/7/29 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. Re: TRNSYS-users Digest, Vol 67, Issue 65 (Jeff Thornton)



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users