[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Parametric Analysis using TRNSYS



Dear Nino Losurdo,

The way I would implement parametric analysis with buildings is to create multiple buildings(with different thickness and thermal properties as you mentioned), *.bui's, and then to ASSIGN different logical unit numbers to these different buildings. Then you run the parametric table with the different logical unit numbers for that particular parameter.

Best regards,

Matt Duffy


----- Original Message -----
From: "Nino Losurdo" <ninolosurdo@gmail.com>
Sent: Mon, August 2, 2010 6:08
Subject: [TRNSYS-users] Parametric Analysis using TRNSYS


Hi my name is Nino Losurdo,
I need to have parametric analysis using Trnsys to simulate different configuration of walls and windows (es. changing insulation thickness or conductivity proprieties). I see that using Trnedit is not possible to set as parameter thickness or thermal proprieties of wall types, maybe because TRNSYS need to calculate transfer function coefficient before starting simulations. Is that any way to do that?
Sorry for my english
 
Kind Regards
 
Nino Losurdo


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users