[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] shades in openings by type67 and 68




Dear Laia,

You could create the window not as an opening in the wall, but as an "aditional window" which is not linked to any wall.
This way you can assign a different orientation to each of them. Then you can link the shading device to the orientation referred to the shaded element while mantaining the unshaded orientation for the other surface.

Hope that helps.



--------------------------------------------------------------------------
Roberto Garay Martinez
Labein-Tecnalia
Unidad de Construcción y Desarrollo del Territorio
c/Geldo. Parque Tecnológico de Bizkaia
Edificio 700
48160 Derio (Bizkaia)
Tel.: 34 94 607 33 00
Fax: 34 94 607 33 49
www.labein.es
---------------------------------------------------------------------------
Visite nuestro blog:
http://www.energiaenedificacion.com
--------------------------------------------------------------------------



trnsys-users-request@cae.wisc.edu

16/07/2010 12:58

Por favor, responda a
trnsys-users@cae.wisc.edu

Para
trnsys-users@cae.wisc.edu
cc
Asunto
TRNSYS-users Digest, Vol 67, Issue 44





Send TRNSYS-users mailing list submissions to
                trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
                https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
                trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
                trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:

  1. Type 43 external file format and active layer                 activation (Chris)
  2. shades in openings by type67 and 68 (Laia Cases - iMat)

----- Mensaje de Chris <clashmar@shaw.ca> en Thu, 15 Jul 2010 21:05:03 -0600 -----
Para:
trnsys-users@engr.wisc.edu
Asunto:
[TRNSYS-users] Type 43 external file format and active layer activation

  Hello,

I have two questions:

1) I am trying find the input file format required for the Type 43a
(Part Load Performance).  I can't find any documentation that describes
this nor have I found an example.  Can someone point me in the right
direction?

2) I want to create an active layer type but the "Active Layer" radio
button in the Layer Type Manager is greyed out.  How do I make this
available?

Thank you in advance,
Chris Lashmar





----- Mensaje de Laia Cases - iMat <lcases@imat.cat> en Fri, 16 Jul 2010 12:58:23 +0200 -----
Para:
trnsys-users@cae.wisc.edu
Asunto:
[TRNSYS-users] shades in openings by type67 and 68

Hi trnsys users,

how do I manage if in the same facade there are one window(window1) with shade by overhang and by shading mash, and another window(window2) without overhang and with same shading mask as windiow1? as i understand, there is a problem if one use 2 type67 or 2 type68. By the other hand, if I use type68 with type34 for window1 and type 67 for window2, I get less demand of heating for window1 than for window 2, that is not congruent.
I hope it is understanding, any suggestion?

thanks in advance

Laia


--
Laia Cases
Unitat de Condicionament Tèrmic
iMat - Centre Tecnològic de la Construcció
lcases@imat.cat
www.imat.cat
Wellington 23  ·   E-08018 Barcelona
T +34 93 553 97 95
F +34 93 553 97 96
Imprimiu aquest document només si és necessari

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users