[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] cpc help trnsys17



Title: cpc help trnsys17
David,
  Any weather file that has high-quality beam radiation in it should be fine. I would recommend starting with Type15 in the meteonorm (TMY2) format mode. There is a significant amount of TMY2 format weather data provided in the TRNSYS weather data archive for locations around the world.
Best,
 David


On 7/4/2010 02:21, Redpath David wrote:

Hi Is there a particular weather file I need to use with the CPC model type 74? I'm building a hybrid system with an evacuated collector so I need a weather programme that works with both. Thanks

David

David Redpath
Lecturer energy storage
Room 26B16/22B04
School of the Built Environment
University of Ulster
Jordanstown Campus
Shore Road
Newtownabbey
N.Ireland
UK
BT37 0QB
d.redpath@ulster.ac.uk

028 90366169  (lab)
http://www.cst.ulster.ac.uk/

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com