[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Shading of PV panels



Heike,
 There is a component in the TESS Green Building Library (Type551) that is designed for this purpose. It also allows you to make a few different assumptions about how the shaded fraction affects the electrical output since the effect is non-linear. The Type uses more or less the same mathematical algorithms as Type30 but modified to allow for shading on vertical surfaces.
Best,
 David


On 6/22/2010 09:00, Heike Huber-Fauland wrote:

Dear all,

I have to simulate PV –Modules on  window shading panels, with a fix angel of 30°

The  problem is the shading by their own.

I tried to solve the problem with type 64 Wingwall, but it only works with vertical walls.

And  type30  don´t work with the field slope 90°

 

Has someone an idea to solve this problem in Trnsys 16?

thanks in advance for any idea

 

 

Heike

 

Dipl-Ing. Heike Huber-Fauland

 

Technische Universität Wien

Institut für Energietechnik und Thermodynamik

 

Getreidemarkt 9/302

1060 Wien

Tel: (+43-1) 58801-30217

Fax: (+43-1) 58801-30299

Email: heike.huber-fauland@tuwien.ac.at

WWW:   http://www.ite.tuwien.ac.at

 

 

 

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***************************