[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] How coupled EES with TRNsys



Fabien,
  Please make sure that you have the EES professional version. The feature that understands the $Import 'CLIPBOARD' and $Export 'CLIPBOARD' commands are only implemented in the professional version. If you do have the professional version, please let me know which versions of EES and TRNSYS you are using and which operating system you have and I will try to duplicate the problem.
Kind regards,
 David


On 6/17/2010 05:18, Fabien Bertran wrote:
Dears TRNsys users,

i would like coupled EEs with TRNsys but id'ont understand how named variables. I followed this instructions on the example to TRNsys (Call EEs, compressor.ees):

$Import 'CLIPBOARD' inp1, inp2
...
tot=inp1+inp2     {this is an example}
out1=inp1
....

$Export 'CLIPBOARD' out1

When i start the simulation, EES give me an error "There are 2 equations and 5 variables with 2 set with $Import. The problem is underspecifier and cannot be solved."

Thanks

Kind regards
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com