[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Insert a window in a wall with a boundary condition



Jade,
 I would treat the window in the "additional windows" category and reduce the area of your BOUNDARY wall accordingly.
Best,
 David


On 5/7/2010 08:09, Jade Deltour wrote:

Hello,

I am modeling a local as single zone with boundary condition. I would like to insert a window to one of the walls of the  local. But with the boundary condition, I couldn’t. To resolve this problem, I defined the window surface as a part of the wall with massless layer and the corresponding resistance.

 Is it an other solution (maybe more realistic) to insert a window in a wall with a boundary condition?

Thanks in advance,

Kinds Regards,

 

Jade Deltour

-----------------------------------------------------------------------------------------------------------------------------------

archetclimat.jpg

Jade Deltour, Ir civil en Mathématiques Appliquées.

UCL - ARCHITECTURE ET CLIMAT

 

Tél  :+32 10/47.91.52

Fax  :+32 10/47.21.50

http://www-climat.arch.ucl.ac.be

Place du Levant,1 B-1348 Louvain-la-Neuve

-----------------------------------------------------------------------------------------------------------------------------------

 logo_Plea2011_xsm Visitez www.plea2011.be

 

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users