I’ve created a Distributable file and copied all files
that I need into the same directory. I am getting a fatal error when
running the Distributable by itself. I don’t get any errors when I
run the simulation within Trnedit. The error reads as follows: *** Fatal Error at time
: 0.000000 Generated by Unit
: 33 Generated by Type
: 96 TRNSYS Message 71 : An
ASSIGNED logical unit number is already in use, either by the TRNSYS kernal or
by a Type Reported information : Not available Attached is the section within the .trd file for Type 96 as
used in my simulation. I’ve scoured it without finding obvious
problems. I haven’t found the logical unit numbers duplicated
elsewhere in the list file either. Any deeper insights on what may be the problem, or other
things to check, would be most appreciated. Kent Beason Schlitterbahn Development Group 830-609-8904 m 830-608-8040 f |
* Model "Type96" (Type 96) * * **|* **|* *** Model Type96 (Type 96, Unit 33) **|* CONSTANTS 3 **|*PARAMETERS VALUES UNITS SWITCHTO= 1.0000000000000E+00 **|Switch to observe off-peak weekend rates |-|-|0|1|0|1.000|1000 SWITCHT1= 1.0000000000000E+00 **|Switch to observe off-peak holiday rates |-|-|0|1|0|1.000|1000 MAXIMUME= 1.0000000000000E+04 **|Maximum excess power |W|W|0|1|-1000000.00000|1000000.00000|1000 CONSTANTS 1 **|*INPUTS VALUES UNITS PARALLEL= 0.0000000000000E+00 **|Parallel generation |W|W|0|1|-1000000.00000|1000000.00000|1000 * UNIT 33 TYPE 96 Type96 *$UNIT_NAME Type96 *$MODEL .\Utility\Utility Rate Schedule Processors\Type96.tmf *$POSITION 1089 240 *$LAYER Main # PARAMETERS 6 53 ! 1 Logical unit number for rate schedule input file 54 ! 2 Logical unit number for text output 55 ! 3 Logical unit number for spreadsheet output SWITCHTO ! 4 Switch to observe off-peak weekend rates SWITCHT1 ! 5 Switch to observe off-peak holiday rates MAXIMUME ! 6 Maximum excess power INPUTS 8 31,1 ! Type95a:Hour of day ->Hour of the day 31,2 ! Type95a:Hour of year ->Hour of the year 31,5 ! Type95a:Month ->Month 31,7 ! Type95a:Year2 ->Year Building_Latent ! Equa:Building_Latent ->Building load 31,8 ! Type95a:Weekend Flag ->Flag indicating weekend 31,9 ! Type95a:Holiday flag ->Flag indicating holiday 0,0 ! [unconnected] Parallel generation *** INITIAL INPUT VALUES 1 1 1 1999 0 0 0 PARALLEL *** External files ASSIGN "Type96-UtilityRateScheduler.dat" 53 **|? Where is the utility rate schedule input file located? |1000 ASSIGN "UtilityBill.txt" 54 **|? Where should the text based utility bill output file be created? |1000 ASSIGN "UtilityBill.dat" 55 **|? Where should the spreadsheet utility bill output file be created? |1000