Hi Knut Erik
It looks like this is the main question remaining on your greenhouse
simulation.
I would set convection coefficients to zero (or a very small number if
zero isn't accepted), and us a separate method to define the air
exchange between the two zones with a coupling when the screen is
open. The large direct air exchange between the zones renders any
convection coefficient meaningless.
Regards
Erik
knut.erik.enerstvedt@niva.no wrote:
Hello,
I have an ADJACENT window (with
shading)
between two Type 56 zones to model a controlled screen which can be
either
pulled across or pulled away. Does anybody know what the convective
heat
transfer coefficients of the window should be when the screen is pulled
away (that is, when the window is "gone" and there is just a
large opening between the zones)?
All help is higly appreciated.
Regards,
Knut Erik Enerstvedt
------------------------------------------------------------------------------------------------------------
Meld deg på vårt nyhetsbrev på www.niva.no
|