[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] TRANSFERFUNCTION COEFFICIENTS



  Hi,
I tested calculation the Conduction heat flux from the wall at the outsideside surface (qso) and Conduction heat flux from the wall at the inside surface (qsi) with the coefficients of transfer given by TRnbuild but I do not obtain same the results as TRNSYS by comperant them with QCOMI (NTYPE 19) and QCOMO (NTYPE 19).
is what you can help me?
best regards
 
 WALL TYPE WALL001             ----------
 
       THERMAL CONDUCTANCE, U=    63.18000 kJ/h m2K; U-Wert=     4.40567 W/m2K
              (incl. alpha_i=7.7 W/m^2 K and alpha_o=25 W/m^2 K)
 
                        TRANSFERFUNCTION COEFFICIENTS
   K            A              B              C              D
 
   0       1.3146198E+02    3.0164527E+01    1.3146198E+02    1.0000000E+00
   1      -7.3051942E+01    2.9298527E+01   -7.3051942E+01   -5.2510413E-02
   2       1.4523889E+00    3.9936285E-01    1.4523889E+00    3.9894507E-07
   3      -6.7559071E-06    1.2396487E-06   -6.7559071E-06
  SUM      5.9862417E+01    5.9862417E+01    5.9862417E+01    9.4748999E-01
 
 
 4 | QCOMI_S1                  | kJ/hr      |   1 | Z1                   |   1 | inside surface conv-l-wave gain >WALL=WALL001:ORI=NORTH                                                                             | QCOMI  1
* |   5 | QCOMO_S1                  | kJ/hr      |   1 | Z1                   |   1 | outside surface conv-l-wave gains->WALL=WALL001:ORI=NORTH                                                                             | QCOMO  1