[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] weather data Type 109 for the building example




Dear Karalis Lampros,

I highly recommend reading in your own data with Type9 and then using the radiation processor, Type16, to use to connect to your building. We are phasing out of Type109 because its source code is very vague, but we are including a new component with the same file format. Nonetheless, I can send you an example with Type9 upon your request.

Best regards,

Matt Duffy

----- Original Message -----
From: "Lambros Karalis" <lkaralis@metal.ntua.gr>
Sent: Wed, October 21, 2009 8:27
Subject: [TRNSYS-users] weather data Type 109 for the building example

Dear Support,

 

While  learning how to use TRNSYS, I study the building example. I would like to use weather data I have for my building instead of those that are already included at the example (iwec_geneva.109)

So I wrote a file ‘Lavrion_2007.109’ following the documentation specifications and by double clicking the icon ‘Type 109 – User’ I changed the weather data file field to point to my new file.

 

After that I tried to run the simulation, but unfortunately I got at error ‘Integer overflow’.

 

Any ideas why did this occur? Attached to this message you will find my weather file.

 

Thanks a lot in advance

 

Karalis Lampros


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users