Re: [TRNSYS-users] New component / changing number of variables inCVF



Dear Knut-Erik, dear Jeff, dear all,

 

thank you for your quick responses. Even though the compilation was error-free, no changes appeared in the performa. Once again, I checked all options I have in order to manipulate the performa in TRNSYS studio and it should come out that after changing outputs in the fortran code and re-compiling the given Type, one has to

1.      open the “Performa” of the given Type in TRNSYS studio,

2.      include the given changes here,

3.      click “propagate properties” (top row of TRNSYS studio),

4.      check all the boxes in the “propagate properties / inheritance settings” window and

5.      click “ok”.

 

Thank you once again!

 

Yours,

 

mathaeus


Mathaeus Nierzwicki

Forschung / Research
Institut für Solartechnik SPF: Adresse / Website
Hochschule für Technik Rapperswil HSR
Tel. +41 55 222 48 30
Fax +41 55 222 48 44


 

From: Jeff Thornton [mailto:thornton@tess-inc.com]
Sent: Freitag, 9. Oktober 2009 23:01
To: knut.erik.enerstvedt@niva.no; Nierzwicki Mathaeus Lukas (mathaeus.nierzwicki@solarenergy.ch)
Cc: trnsys-users@cae.wisc.edu
Subject: Re: [TRNSYS-users] New component / changing number of variables inCVF

 

After re-compiling the source code did you link it to create a new DLL which contains your changes?  You may also have to remove any other DLL's that contain the previous source code....

Jeff

Jeff Thornton
President - TESS, LLC

22 North Carroll Street - Suite 370
Madison WI 53703 USA

Phone: 608-274-2577
Fax: 608-278-1475
E-mail: thornton@tess-inc.com
Web: www.tess-inc.com






----- Original Message -----

From: "" <knut.erik.enerstvedt@niva.no>
Sent: Fri, October 9, 2009 1:57
Subject: Re: [TRNSYS-users] New component / changing number of variables inCVF


Mathaeus,

I the number of outputs in the source code matches the number of outputs in the Proforma, then you should see the correct number of outputs when using your new component in the Studio. Make sure that you set Role to "output" when you define the new variable in the Proforma. You can click on the Outputs tab (after clicking on Variables) to see a list of all output variables.

Hope this helps,

Knut Erik  




Dear all,
 
I am programming a new type for TRNSYS using Compaq Visual Fortran (cvf) and I would currently like to add some outputs. I alread y changed the number of outputs in the fortran environment to
 
1)      NOUT=2,
2)      I performed a simple calculation, eg a=2,
3)      and set an output as OUT(2)=a .
 
After recompiling still no changes appeared so I decided to extend the number of variables in my trnsys type environment (performa).
 
Even though, no changes appear – there is only one output available in the TRNSYS project environment.
 
Does any of you know an appropriate solution?
 