Re: [TRNSYS-users] New component / changing number of variables in CVF




Mathaeus,

I the number of outputs in the source code matches the number of outputs in the Proforma, then you should see the correct number of outputs when using your new component in the Studio. Make sure that you set Role to "output" when you define the new variable in the Proforma. You can click on the Outputs tab (after clicking on Variables) to see a list of all output variables.

Hope this helps,

Knut Erik  




Dear all,
 
I am programming a new type for TRNSYS using Compaq Visual Fortran (cvf) and I would currently like to add some outputs. I already changed the number of outputs in the fortran environment to
 
1)      NOUT=2,
2)      I performed a simple calculation, eg a=2,
3)      and set an output as OUT(2)=a .
 
After recompiling still no changes appeared so I decided to extend the number of variables in my trnsys type environment (performa).
 
Even though, no changes appear – there is only one output available in the TRNSYS project environment.
 
Does any of you know an appropriate solution?
 
Sincerely
 
Mathaeus
 




------------------------------------------------------------------------------------------------------------
Meld deg på vårt nyhetsbrev på