there is no output on the heat transfer of the active layer to the room, but only on the heat transfered from the fluid to the wall (NTYPE59). Once given to the wall it is not possible to decide where the energy is going (to be stored, going to inside, to outside ...) as there is other heat transfer to the wall. Please have a look at the wall energy balance (NType 906).
Best regards
Monika
----- Originalnachricht -----
Von: senne plessers <senne_plessers@hotmail.com>
Gesendet: Mon, 9/7/2009 2:34pm
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] Heat transfer
Dear all,
I have a question about the heat tranfer from an active layer to a room.
Is there an output from type 56 I can use to calculate that? Or can I use
a component from the access tree?
Thanks in advance,
Kind regards,
Senne