[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] 96360 hours problem ?



Sorry about the message, it was my fault : my simulations were made using a demand modeling that lasts only 96360 hours. I modified the files (equations) and everything is fine.

 

So this is not TRNSys’s fault.

 

Clement

 

 


De : David Bradley [mailto:bradley@tess-inc.com]
Envoyé : mardi 4 août 2009 00:27
À : REBILLARD, Clement (Stagiaire CRPE)
Cc : trnsys-users@cae.wisc.edu
Objet : Re: [TRNSYS-users] 96360 hours problem ?

 

Clement,
 Can you send the text of the error message that is being written to the *.log or *.lst file?
Kind regards,
 David


REBILLARD, Clement (Stagiaire CRPE) wrote:

Dear users,

 

I am successfully running simulations (CSHPSS simulations) on TRNSys but recently i tried to incrase the simulation time to more than 10 years (87600 hours). At 96360 hours, a parameter stops to get its value and my simulation is false after that time.

 

I isolated the problem and it comes from the modelisation of the demand : I am using « equations » to model the demand and the flow rate of the demand (on the outside of the heat exchanger) is calculated thanks to the Power and Temperature difference : Flow = Power / Cp / Delta(T)

 

Moreover, if stating START=96000 and STOP=1752000, the same problem occurs at 96360 hours.

 

Has anyone had the same problem and does anyone know how to solve it ?

Many thanks,

 

Clement Rebillard

Veolia Environment

 

___________________________________________________________________________________

Protegeons ensemble l'environnement : avez-vous besoin d'imprimer ce courrier electronique ?
___________________________________________________________________________________

Les informations figurant sur cet e-mail ont un caractere strictement confidentiel et sont exclusivement adressees au destinataire mentionne ci-dessus.Tout usage, reproduction ou divulgation de cet e-mail est strictement interdit si vous n'en etes pas le destinataire. Dans ce cas, veuillez nous en avertir immediatement par la meme voie et detruire l'original. Merci.

This e-mail is intended only for use of the individual or entity to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law.
Any use, distribution or copying of this e-mail communication is strictly prohibited if you are not the addressee. If so, please notify us immediately by e-mail, and destroy the original. Thank you.

 



 
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
  



-- 
***********************************************************************
Thermal Energy System Specialists (TESS), LLC 
David BRADLEY                      22 N. Carroll Street - Suite 370 
Partner                            Madison, WI 53703 
                                   USA
P: +1.608.274.2577 
F: +1.608.278.1475
E-mail: bradley@tess-inc.com 
Web Pages:  http://www.tess-inc.com    and      http://www.trnsys.com
 
***********************************************************************
 
___________________________________________________________________________________

Protegeons ensemble l'environnement : avez-vous besoin d'imprimer ce courrier electronique ?
___________________________________________________________________________________

Les informations figurant sur cet e-mail ont un caractere strictement confidentiel et sont exclusivement adressees au destinataire mentionne ci-dessus.Tout usage, reproduction ou divulgation de cet e-mail est strictement interdit si vous n'en etes pas le destinataire. Dans ce cas, veuillez nous en avertir immediatement par la meme voie et detruire l'original. Merci.

This e-mail is intended only for use of the individual or entity to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law.
Any use, distribution or copying of this e-mail communication is strictly prohibited if you are not the addressee. If so, please notify us immediately by e-mail, and destroy the original. Thank you.