Ali, There is no rule as to what the input file is called as far as Studio is concerned. However, if you are trying to run multiple input files (*.dck) that have already been generated, I would recommend that you use either a batch file and the command: "c:\Program Files\Trnsys16_1\Exe\TRNExe.exe" "c:\Program Files\Trnsys16_1\MyProjects\...\NameOfInputFile.dck" /n or that you run a parametric table from TRNEdit in which the input file name stays the same but a certain CONSTANT statement is varied from one run to the next. In this case, the individual *.dck files will be created as each parametric table run starts. Kind regards, David Ali Al-Alili wrote:
-- *********************************************************************** Thermal Energy System Specialists (TESS), LLC David BRADLEY 22 N. Carroll Street - Suite 370 Partner Madison, WI 53703 USA P: +1.608.274.2577 F: +1.608.278.1475 E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com *********************************************************************** |