Ali, There is no rule as to what the input file is called as far as Studio is concerned. However, if you are trying to run multiple input files (*.dck) that have already been generated, I would recommend that you use either a batch file and the command: "c:\Program Files\Trnsys16_1\Exe\TRNExe.exe" "c:\Program Files\Trnsys16_1\MyProjects\...\NameOfInputFile.dck" /n or that you run a parametric table from TRNEdit in which the input file name stays the same but a certain CONSTANT statement is varied from one run to the next. In this case, the individual *.dck files will be created as each parametric table run starts. Kind regards, David Ali Al-Alili wrote:
--
***********************************************************************