[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] (no subject)



Max,
 There is a hard limitation of 5 online plotters in TRNSYS 16. There are some data structures in the Fortran code which you could modify but those same structures are mirrored in the TRNExe.exe code, which is not accessible.
Kind regards,
 David


Max Werlein wrote:
Dear Trnsys-users,

I'd like to enabable TRNSYS to use (or plot) more than 5 Online plotters. I have not find any answers saying it was possible so i assume it's not. nevertheless I have found a common block defing the array used for type 65 in the TrnsysData.for, which leads me to think it might be possible somhow anyway. I would be very thankfull for any suggestions, since Trnsys 17 will not be released until summer.

Greeting and thanks

max


Adminístralas todas usando Windows Live Mail. ¡Descárgalo gratis! ¿Tienes más de una cuenta de correo?

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***********************************************************************
Thermal Energy System Specialists (TESS), LLC 
David BRADLEY                      22 N. Carroll Street - Suite 370 
Partner                            Madison, WI 53703 
                                   USA
P: +1.608.274.2577 
F: +1.608.278.1475
E-mail: bradley@tess-inc.com 
Web Pages:  http://www.tess-inc.com    and      http://www.trnsys.com

***********************************************************************