[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] wiring node temperature outputs of type 60 - (TRNSYS16-01-003)



David,
  The node temperatures are the last set of outputs of Type60. In the proforma, make sure that you have answered the question about how many nodes there are both in the "outputs" tab and in the "derivatives" tab.
Kind regards,
 David


David Chèze wrote:

Hello,

 

Is there another way than equations to wire node temperature outputs of type 60 in the studio : these outputs are not visible when wiring the proformas.

 

Thanks for your help.

 

David Chèze

CLIPSOL / R&D

 


_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***********************************************************************
Thermal Energy System Specialists (TESS), LLC 
David BRADLEY                      22 N. Carroll Street - Suite 370 
Partner                            Madison, WI 53703 
                                   USA
P: +1.608.274.2577 
F: +1.608.278.1475
E-mail: bradley@tess-inc.com 
Web Pages:  http://www.tess-inc.com    and      http://www.trnsys.com

***********************************************************************