While working and modifying type 396 (trough) of the TESSlib, I found an inconsistency between the way the type calculates its thermal efficiency and the formula in which the loss coefficients are given in the sources [2] and [8] in the manual:

In sources [2] and [8], the thermal efficiency is always given as
Ceff=K*(A+B*(DTo+DTi)/2) + (C+Cw*WS)*(DTo+DTi)/(2*Ieff) +D/(Ieff)*((DTo+DTi)/2)**2)

where K is the IAM, A,B,C,Cw and D are collector specific coefficients and (DTo+DTi)/2 the average temperature difference collector to ambient.

In the type, the equation is
Ceff=K*M*Sh*[(A+B*(DTo+DTi)/2)+(C+Cw*WS)*(DTo+DTi)/(2*I)+D/I*(DTo*DTi+(DTo-DTi)**2/3)]
while the same coefficients as in the sources are said to be used.

(M & Sh are calculated coefficients for end losses and shading)

The IAM factor K (as well as M and Sh) is multiplied with the complete equation instead of only the first term. Additionally, the use of the temperature difference in the last term seems to be not correct. Both differences will affect the "behavior" of the collector in the simulation.


If I am not mistaken, the type should be corrected before use.

Best regards,
Jochen

--