Hello Cedric,
to increase the number of parameters you have to change the value of
nMaxParameters in the file \Sourcecode\Kernel\TRNSYSConstants.for. Afterwards
you need to recompile the TRNDll.dll. You can find instructions on
recompiling the TRNDll.dll in chapter 8.5 of the TRNSYS
Manual.
Best regards,
Mathieu
Dipl.-Ing. Mathieu
Riegger
Solites Steinbeis Forschungsinstitut für solare und zukunftsfähige thermische Energiesysteme Steinbeis Research Institute for Solar and Sustainable Thermal Energy Systems Nobelstr. 15, 70569 Stuttgart, Germany Tel.: +49 711/6732000-50, Fax.: +49 711/6732000-99 Email: riegger@solites.de, Internet: www.solites.de Ein Unternehmen im Verbund der
Steinbeis-Stiftung Von: PAULUS Cedric 217865 [mailto:cedric.paulus@cea.fr] Gesendet: Montag, 17. November 2008 15:54 An: trnsys-users@cae.wisc.edu Betreff: [TRNSYS-users] maximum number parameter simulation Hello, I?ve got this
message : TRNSYS
Message 46 : The total number of PARAMETERs in the
entire simulation has exceeded the maximum number of parameters allowed by
TRNSYS. Reduce the number of required parameters by eliminating
unnecessary TYPES if possible or increase the limit on the number of parameters
allowed.
Reported information : Error
46 Does anyone know how to increase the
limit on the number of parameters allowed in one simulation
? Thanks Cédric
PAULUS |