[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Problem with type 65



Sorry for the mistake in my previous mail : it's not right to convert directly kJ/h in kWh! You have to convert kJ/h in KW and then integrate that value to obtain kWh (Type 24).
 
Sorry for that desagrement.

Best regards, Adrien

Jeff Thornton a écrit :
Well you're mostly right.  You can't convert kJ/h to kWh as one is power (time rate of energy) and one is energy.  You can of course convert kJ/h to kW by dividing by 3600 or convert kJ/h to kWh/h by using the same equation.  If you really want to plot kWh then you need to integrate the kJ/h power rate from the Type 56 outputs and then divide the integrated value by 3600 to get kWh.

Jeff

Jeff Thornton
President - TESS, LLC

2916 Marketplace Drive - Suite 104
Madison WI 53719 USA

Phone: 608-274-2577
Fax: 608-278-1475
E-mail: thornton@tess-inc.com
Web: www.tess-inc.com



----- Original Message -----
From: "Adrien JEZEQUEL - ITF" <a.jezequel@itf.biz>
Sent: Fri, November 14, 2008 8:11
Subject: Re: [TRNSYS-users] Problem with type 65

Dear Kiki,

You can use an equation tool (Assembly - Insert New Equation) between Type56 and Type 65 to convert your outputs in KWh (divide heating and cooling outputs by 3600 to obtain KWh).

Best regards,

Adrien

kiki siouna a écrit :
Dear Trnsys users,
 I simulate a building with trnsys 16.1and i have a problem with types 65 outputs.I want plotter to appear the heating and cooling demands in kWh and not in kJ/h.What I have to do??

Best regards
Kiki Siouna



_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

--

www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
87, Avenue de Chambéry
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
  

--

www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
87, Avenue de Chambéry
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email