Re: [TRNSYS-users] Negative field slope in type 30



Giovanni,
 I believe that the error is in the proforma; the algorithm that Type30 uses assumes that the field slope is either zero or positive.
Kind regards,
 David


giovanni nurzia wrote:
Dear All,
I get "field slope out of range" in type 30 if I put a negative value (which is teoretically allowed in the proforma).

 The following statement in the code could be the reason:
IF(SLFLD.GE.0.0 .AND. SLFLD.LE.SLCL .AND. SLFLD.LT.1.50) GO TO 77
               CALL TYPECK(4,INFO,NI,NP,0)
          CALL MESSAGES(-1,'Field Slope is out of range','fatal',INFO(1),INFO(2))

Any suggestion?
kind regards,
 
Giovanni Nurzia