[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] error creating a wall type Trnsbuild



Dear Amandine,

You have to increase your time base calculation in TRNBUILD (Edit Building - Outputs - TIMEBASE (default value = 1).

Best regards, Adrien

Amandine Le Denn a écrit :
 
Dear TNRSYS users,
 
I created  walls in my TRNBuild simulation and an error message appears when registering:"Error creating the wall transfert function coefficients: Unable to find a root after indication that a root exists. Maybe the timebase is too small. Please, check the INF-file further information."
I do not see where is the problem. Thank you for your help.
 
Best regards,
 
HAMADI Malik - Amandine LE DENN

 


---------------------------------------------------------------------------------------
Orange vous informe que cet e-mail a été contrôlé par l'anti-virus mail.
Aucun virus connu à ce jour par nos services n'a été détecté.



_______________________________________________ TRNSYS-users mailing list TRNSYS-users@engr.wisc.edu https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

--

ITF
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF (Ingénierie Tous Fluides)
87, route de Chambéry
73230 ST ALBAN EN LEYSSE
FRANCE
Tel: 04.79.75.00.29
Website: www.itf.biz
Mail : a.jezequel@itf.biz