Lotta,
You are correct that there is no limitation in DynamicData. I also had a
look at the Type71 code and there is nothing in there preventing you
from having more than 10 values of IAM. The restriction is in the Type71
proforma itself. What you will need to do is modify the Type71 proforma
to increase the maximum value allowed for that particular parameter,
save the change, then perform an Edit: Replace on the component that is
in your project. Modifications made to proformas are not automatically
made to projects that contain those proformas.
Kind regards,
David


Lotta Koch wrote:
Dear all,

I would like to use Type 71 (Evacuated tube solar collector) with a higher number of longitudinal an tranverse angles for which IAMs ara provided. In the mathematical description of the type is written that it is limited to 10, but until now I hope that is only a question of the format of the IAM-data. Does anybody know how you can change this format? The interpolation-function DYNAMICDATA is not limited in sampling points as I understand.

Thanks a lot for a hint!

Lotta Koch
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users




--
***********************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                      2916 Marketplace Drive - Suite 104
Partner                            Madison, WI 53719
                                  USA
P: +1.608.274.2577
F: +1.608.278.1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com    and      http://www.trnsys.com

***********************************************************************