Hi Fuqiao,
I just set the cooling
power in a project of mine to a variable value and it works just fine. Did you
connected Q_HEATING to the correct input?
Regards,
Met vriendelijke groet,
|
Jan-Willem van Laer, Assistent
Projectleider
|
|
Bezoekadres:
|
Boterdiep 48, 3077 AW Rotterdam
|
Postadres:
|
Postbus 9222, 3007 AE Rotterdam
|
Telefoon:
|
010 - 4257444
|
Fax:
|
010 - 4254443
|
E-mail:
|
j.vanlaer@chri.nl
|
Web:
|
www.chri.nl
|
|
|
KvK-nummer:
|
14623897
|
Disclaimer:
|
Op deze e-mail is een
disclaimer van toepassing:
A disclaimer is applicable to this e-mail, please refer to:
http://www.chri.nl/emaildisclaimer
|
Van:
Fuqiao.Wang@fulcrumfirst.com [mailto:Fuqiao.Wang@fulcrumfirst.com]
Verzonden: donderdag 3 januari
2008 11:46
Aan:
Timo.Sengewald@bls-energieplan.de; trnsys-users@engr.wisc.edu
Onderwerp: Re: [TRNSYS-users]
type56 Bugs?
hi, all
in type 56, in cooling/heating type
manager, you can not set the cooling/heating power as input variable, they do
not work! however, if you use unlimited power or constant, it works pretty well
!
Can anybody try this and tell me why?
Fuqiao
Wang
Sustainable Consulting Engineer
FULCRUM CONSULTING
London: Tel: +44 (0)20
7520 1300/1305
Edinburgh: Tel: +44 (0)131 226 0220
Spain: Tel: +34 98
5195989
mailto:Fuqiao.Wang@fulcrumfirst.com
www.fulcrumfirst.com
From:
Timo Sengewald [mailto:Timo.Sengewald@BLS-Energieplan.de]
Sent: 2008年1月3日
10:33
To: trnsys-users@engr.wisc.edu
Subject: [TRNSYS-users] type56
Bugs?
No idea what this may be. It would be helpful if you sent
your .bui and .dck to the list. Perhaps some body else can have a look at it,
too.
Von:
Fuqiao.Wang@FulcrumFirst.com [mailto:Fuqiao.Wang@FulcrumFirst.com]
Gesendet: Donnerstag, 3. Januar
2008 11:25
An: Timo Sengewald
Betreff: RE: [TRNSYS-users] type56
Bugs?
hi, Timo
the room temperature does not change when
you are using this type as shown.
(I mean no matter how big input
value you gave. the room temperature still went upto 40 even you set the
temperature at 26 deg C, however, if a constant being inputted, it works pretty
well! )
(the similar things happens in heating
type mode! )
thank you for your quick response.
Regards
Fuqiao
Wang
Sustainable Consulting Engineer
FULCRUM CONSULTING
London: Tel: +44 (0)20
7520 1300/1305
Edinburgh: Tel: +44 (0)131 226 0220
Spain: Tel: +34 98
5195989
mailto:Fuqiao.Wang@fulcrumfirst.com
www.fulcrumfirst.com
From:
Timo Sengewald [mailto:Timo.Sengewald@BLS-Energieplan.de]
Sent: 2008年1月3日
10:07
To: Fuqiao Wang
Subject: AW: [TRNSYS-users] type56
Bugs?
Fuqiao,
what in detail is the problem? All seems fine in the screen
shot. What happens when you run the simulation?
BLS Energieplan GmbH
i. A. Timo Sengewald
Elsenstraße 106
D-12435 Berlin
Tel.: +49 30 53 32 81-0
Fax: +49 30 53 32 81-40
____________________________________________________
BLS Energieplan GmbH
Sitz der Gesellschaft: Berlin
Geschäftsführer: Christoph Lange, Wolfgang Sturm
Registergericht: Amtsgericht Berlin-Charlottenburg, HRB-Nr. 32021
Von:
Fuqiao.Wang@fulcrumfirst.com [mailto:Fuqiao.Wang@fulcrumfirst.com]
Gesendet: Donnerstag, 3. Januar
2008 10:38
An: trnsys-users@engr.wisc.edu
Betreff: [TRNSYS-users] type56
Bugs?
Dear All
Happy new Year!
please help me with my problem as attached. in Type 56, when a cooling type
being set as an input limited power, it does not work. I 've tried this power
by using a constant, or unlimited power, both work fine.
what's wrong with it?
Thank you in advance.
Best wishes
Fuqiao Wang
Sustainable Consulting Engineer
FULCRUM CONSULTING
London: Tel: +44 (0)20 7520 1300/1305
Edinburgh: Tel: +44 (0)131 226 0220
Spain: Tel: +34 98 5195989
mailto:Fuqiao.Wang@fulcrumfirst.com
www.fulcrumfirst.com
-----Original Message-----
From: trnsys-users-request@engr.wisc.edu
[mailto:trnsys-users-request@engr.wisc.edu]
Sent: 2008年1月2日
18:03
To: trnsys-users@engr.wisc.edu
Subject: TRNSYS-users Digest, Vol 37, Issue 1
Send TRNSYS-users mailing list submissions to
trnsys-users@engr.wisc.edu
To subscribe or unsubscribe via the World Wide Web, visit
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
trnsys-users-request@engr.wisc.edu
You can reach the person managing the list at
trnsys-users-owner@engr.wisc.edu
When replying, please edit your Subject line so it is more specific than
"Re: Contents of TRNSYS-users digest..."
Fulcrum Consulting is proud to be a Founding Member of the UK Green Building Council. To find out more
visit http://www.ukgbc.org
*******************
email confidentiality notice *************************
This
message is intended for the addressee recipient only. It is private and
confidential. If you have received this message in error, please notify the
sender immediately and remove it from your system. If you are not the intended
recipient you must not use, disclose, distribute, copy, print or rely on this
email. Fulcrum First Ltd Incorporated in England and Wales with Registered
Number: 03401753. Registered Office: 62-68 Rosebery Avenue, London EC1R 4RR
*************
Fulcrum First Ltd trading as Fulcrum Consulting *************