Eleni,
Type703 should be in the Ground Coupling library DLL that is
located in either the ..\Trnsys16_1\UserLib\DebugDLLs\ or the
..\Trnsys16_1\UserLib\ReleaseDLLs\ directory. Depending on whether
your TRNDll.dll was compiled in debug or release mode, the ground
coupling library DLL should be automatically loaded from the
appropriate place. Could you please check and make sure that there is
are files called:
..\Trnsys16_1\UserLib\ReleaseDLLs\TESSGroundCouplingLibrary_ReleaseVersion204.dll
and
..\Trnsys16_1\UserLib\DebugDLLs\TESSGroundCouplingLibrary_DebugVersion204.dll
if they are missing, then backup copies of those DLLs are located in
..\Trnsys16_1\Tess Models\DLLs\
Cheers,
David
At 09:21 12/4/2007, Eleni Ampatzi wrote:
Dear All,
I get the following error when using type 703 (TESS).
"Fatal Error at time : 0.000000
Generated by Unit : 12
Generated by Type : 703
TRNSYS Message 105 : A TYPE was called in the TRNSYS input
file but was either not linked
into trndll.dll or was not found in an external dll. A dummy
subroutine was called in its place.
Please link the TYPE or remove it from the input file"
How do I link type 703 into trndll.dll ? (and then I build the
library I guess...). Thank you in
advance,
Best Regards
Eleni
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY 2916 Marketplace Drive - Suite 104
Partner Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages: http://www.tess-inc.com and http://www.trnsys.com
"Providing software solutions for today's energy engineering projects"
****************************************************************************************