[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] type28b



Title: Nachricht
Hi Filippo,
 
to get informations by using this type you need to define what you want to be printed by setting the operation codes. The commands for this are
a little bit tricky (see the manual mathematical references for type 28). I will give you an example.
 
1 Operation code: -11 (takes the first input)
2 Operation code: -4 (Prints it in the file)
 
If you don't define what has to be calculated (operation code = 0) you get no information.
I hope this will help you.
 
With kind regards,
Christian
-----Ursprüngliche Nachricht-----
Von: Filippo Chiettini [mailto:ceten37@hotmail.com]
Gesendet: Montag, 1. Oktober 2007 14:16
An: trnsys-users@engr.wisc.edu
Betreff: [TRNSYS-users] type28b

Hi,
i have a problem with the type28b.
Even if i specify 5 inputs, after the simulation i get only the line with the month and the time but not the integrated value of my inputs. I get only the label with the month and the time, nothing else.
I have specified only one operation mode set to zero (i don´t really understand what it is for, but even if i put 5 of them nothing changes).
If you can give me an advice..
 
Thank you,
 
Filippo
 


Gioca a Ladybird, il nuovissimo gioco di Windows Live Messenger!