[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Several Type65c



OK, that's clear, many thanks

gizmoog
David Bradley a écrit :
The order of the Type65 tabs along the bottom is determined by the order in which the Type65s appear in the input file. The first Type65 that appears in the input file determines the number of plots in the simulation, and the number of x-axis grid points for all of the plots (since the x-axis cannot change from one plot to another). You can determine or change the order of Type65s by clicking on the "component order" tab in the simulation control cards icon (where you change the simulation start and stop time).
Cheers,
 David


At 03:13 8/24/2007, gizmoog wrote:
Dear all,

Does anybody knows how to specify which Type65c (graph) will be drawn in
case of multiple Type65 in a project ?

regards
gizmoog

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY 2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com

"Providing software solutions for today's energy engineering projects"
****************************************************************************************