Re: [TRNSYS-users] Virtual Window
Adrien,
I believe that we fixed that error but in
order to be sure, can you please send me the copy of prgwin.lib that is in:
..\Trnsys16\Building\Lib\Tess\
Thanks in advance,
David
At 08:29 6/27/2007, Adrien JEZEQUEL wrote:
Dear TRNSYS Users,
I'd like to model a thermal zone with one of its surface totaly opened
to exterior. I use Type56 to model the building. I have tried to define
a wall, with 100 % window area and no frame. The window type I choose is
the "Virtual (open or nonexistent) Window" (WINID 1) from TESS Library.
But unfortunately that way doesn't seem to be the right one. An error
message occurs at the beginning of the run :
/"Iniglasdata value negative or greater than 1 for nonvisual absorption
W4_front was found after fitting for Window-ID 1 : abs_nonvis =
-.0008717874 at angle = 0"/
Could anybody help me in that way? Does anyone have an idea to model that?
Thanks in advanced for your answer.
Best regards, Adrien
***************************************************************
Adrien JEZEQUEL
Ingénieur en Simulations Dynamiques
ITF (Ingénierie Tous Fluides)
87, route de Chambéry
73230 ST ALBAN EN LEYSSE
FRANCE
Tel: 04.79.75.00.29
Website: www.itf.biz
Mail : a.jezequel@itf.biz
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY 2916 Marketplace Drive - Suite 104
Partner Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages: http://www.tess-inc.com and http://www.trnsys.com
"Providing software solutions for today's energy engineering projects"
****************************************************************************************