Samuele,
  My understanding is that this problem arises because the full path of the plugin and the external file that is written by the plugin are not passed (only relative paths are passed). The best way to solve the problem is to copy a *.hol file from the ..\Trnsys16\Tess Models\Applications\ directory into your ..\Trnsys16\MyProjects\...directory, then open the Type519 component, switch to the "External Files" tab, browse for the *.hol file that you want to use in your project, then switch to the Parameters tab and launch the plugin. Modify the *.hol file to your liking, then select save and exit to return to the Studio.
Cheers,
 David


At 10:32 6/13/2007, Samuele wrote:
Dear all,
 
I'm using Type 519a: I have setted the day of the year in the file.hol but an error immediately occurs;
"The data file supplied to the Type 519 schedule component could not be correctly read. Please check the location and contents of this file".
 
Could anybody tell me what the problem is?
 
Thanks in advance.